Jordahl Channel - Load Criteria  
 

Stress ranges of the JTA anchor channels

At right angles to the channel longitudinal axis

Jordahl anchor channels JTA are able to absorb central tension, oblique tension and shear load in accordance with the stress ranges illustrated. In this case, the resultant load must not exceed the permissible loads outlined in the following document:

For dynamic loads, the following anchor channels are approved:


Stress ranges of the anchor channels JXA and JZA

In all directions

In conjunction with toothed bolts, Jordahl anchor channels are able to absorb loadings in all directions. They are approved by the German Institute for Structural Engineering for loads in the channels longitudinal direction. In the event of simultaneous stressing in a plurality of directions, the resultant load must not exceed the permissible loads. For dynamic loads, the following anchor channels are approved: